IGS-type acronym : | MATE |
Latitude : | 40.64910126 |
Longitude : | 16.70450020 |
Installed date : | 1992-02-17 |
Decommissioned date : | |
Country : | ITALY |
City: | MATERA |
Station status : | active (green) |
Domes Nr.: | 12734M008 |
Station operator: | Unknown |
IGS-like station form : |
M | Material change or malfunction |
E | Earthquake |
RF | Reference Frame change |
U | Unknown |
NA | Not available |
Position discontinuity | |
Velocity discontinuity |
Plots generated using software developed with the EPN team at ROB |
||
Observations & tracking performance | Satellite tracking |
The satellite tracking graph has been calculated for all stations for the first day of each month. If you wish to have a graph for another date, choose the 'Calculate a specific date' option.
Please be adviced that on DOY 2020/108 firmware of Leica GR30 receiver
at MATE00ITA (Matera) station has been upgraded from 4.20/7.300 to
4.35/7.504.
At the same time, tracking of Galileo E6, Glonass L3 and Beidou B3
signals has been enabled.
On DOY 2018/206, MATE (Matera, Italy) Leica GR30 firmware was updated
from 4.11/7.102 to 4.20/7.300.
Updated sitelog was submitted to both IGS and EUREF
Please be advised that on DOY 2017/185 at approx 07:00 UTC, data
acquisition of MATE and MAT1 (Matera, Italy) stations will be temporary
stopped in order to replace GNSS receivers.
Data recording will be resumed as soon as possible and update site logs
containing new receivers details will be sent to EUREF/IGS.
Please be advised that on DOY 2017/179 at approx 11:00 UTC, data
acquisition of MATE and MAT1 (Matera, Italy) stations resumed.
Please be advised that on DOY 2017/177 at approx 11:15 UTC, data
acquisition of MATE and MAT1 (Matera, Italy) stations will be temporary
stopped.
Data recording will be recovered as soon as possible.
Please be advised that on DOY 2017/164 at approx 14:00 UTC,
MATE (Matera, Italy) station is again in operation.
Please be adviced that on DOY 2016/274 at approx 13:00 UTC, data
acquisition of MATE (Matera, Italy) was temporary stopped to permit an
urgent and important maintenance on the antenna monument.
Any precaution has been taken to keep antenna position invariated during
this maintenance.
Data recording will be recovered as soon as possible.
In the next upcoming days, site log will be updated to record the changes.
MATE (Matera, Italy) station is experiencing tracking problems like the
other station MATG located at the same facility in Matera.
Few days ago I switched off Galileo tracking on MATG (see may previous
message) in order to see if this results in some change in the station
performance.
One possible (common) cause could be strong RFI at GNSS band(s).
Other could be a problem on the receiver firmware, but we have to
consider that MATE has Leica 1200GGPRO while MATG has Leica 1200 .
I am not in the position to say if and how the receiver firmwares are
similar or completely different.
Investigations are on going and I will keep you informed.