| IGS-type acronym : | CPVG00CPV |
| Latitude : | 16.73206201 |
| Longitude : | -22.93493304 |
| Installed date : | 2013-10-22 |
| Decommissioned date : | |
| Country : | REPUBLIC OF CAPE VERDE |
| City: | PALMEIRA |
| Station status : | active (green) |
| Distance to Tide Gauge (m) : | 5753 |
| Domes Nr.: | 39601M001 |
| Station operator: | (CNES) - Centre National d"Etudes Spatiales (INMG) - Instituto Nacional de Meteorologia e Geofisica |
| IGS-like station form : |
| M | Material change or malfunction |
| E | Earthquake |
| RF | Reference Frame change |
| U | Unknown |
| NA | Not available |
| Position discontinuity | |
| Velocity discontinuity |
![]() |
![]() |
Plots generated using software developed with the EPN team at ROB |
| Observations & tracking performance | Satellite tracking |
(this operation may take 20 to 45s)
The satellite tracking graph has been calculated for all stations for the first day of each month. If you wish to have a graph for another date, choose the 'Calculate a specific date' option.
A firmware upgrade was done for CIBG, CHPG, CPVG, FTNA, JFNG, KERG, MAYG, OWMG, RGDG, SEYG stations (5.45 version for Trimble Alloy/NetR9), on 2020-05-25.
New sitelogs have been submitted to IGS.
A firmware upgrade was done today on CPVG station. The new sitelog has been submitted to IGS.
3.13 Receiver Type : TRIMBLE NETR9
Satellite System : GPS GLO GAL BDS SBAS
Serial Number : 5224K50003
Firmware Version : 5.42
Elevation Cutoff Setting : 0 deg
Date Installed : 2019-10-24T09:36Z
Date Removed : 2020-03-05T14:07Z
Temperature Stabiliz. : 22.0 /- 3.0
Additional Information :
3.14 Receiver Type : TRIMBLE NETR9
Satellite System : GPS GLO GAL BDS SBAS
Serial Number : 5224K50003
Firmware Version : 5.43
Elevation Cutoff Setting : 0 deg
Date Installed : 2020-03-05T14:15Z
Date Removed : CCYY-MM-DDThh:mmZ
Temperature Stabiliz. : 22.0 /- 3.0
Additional Information :
The station CPVG is operational again. The receiver at the station has been replaced the 21st September. A new sitelog has been submitted to IGS.
All the data concerning the period 04/21/17 to 09/21/17 are lost due to a failure on the receiver.
Due to power failure, station CPVG experienced permanent data outage
between 2016-12-13 16:45Z and 2017-03-03 16:15Z
between 2017-03-01 19:30Z and 2017-03-13 11:00Z
The station CPVG is operational since 07/25/16. Due to a potential power failure, all the data between 06/21/16 and 07/25/16 is lost.
CPVG antenna is repaired. Data are now available since 2015-10-24 00:00Z [DOY 297].